FOR THREE PHASE PUMP MOTORS
Sirio is a VFD (Variable Frequency Driver) for pumps. Sirio was made to control the pump’s speed and hold the pressure to a constant value within the hidrofor system. Not only controls the pump, but protect it from:
- Dry running
- Over current
It has a display to show the values of the pump (current absorption, pressure, frequency etc…) and can be set with the buttons on the interface. Sirio must be installed on the pipe system in any position, but according to the flow direction.
If the pump stops by an error, Sirio will display the source of the error, and restart the pump according to the restart parameters.
Power mains supply: | 230 V~ ±10% 50/60Hz single phase |
Motor power output: | 220 V~ three phase |
Max. motor power: | 2200 W |
Max. line absorption: | 16A @ 230 V~ |
Max allowed pressure | 8 bar |
Max fluid temperature: | 50 °C |
Pressure drop: | 0,1 bar at 150 l/min |
Set point adjustement range: | 1,5 – 7 bar |
Start pressure adjustment range: | 1 – 6,7 bar |
Hydraulic connection: | 1″ ¼ male |
Frequency modulation range: | 25 – 50 Hz |
Protection degree: | IP X5 |