<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pressure switch for water Archives - Szivattyúvezérlés</title>
	<atom:link href="https://szivattyuvezerles.hu/category/pressure-switch-water/feed/" rel="self" type="application/rss+xml" />
	<link>https://szivattyuvezerles.hu/category/pressure-switch-water/</link>
	<description>szintszabályozás</description>
	<lastBuildDate>Wed, 13 May 2015 12:35:53 +0000</lastBuildDate>
	<language>hu</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>
	<item>
		<title>Pressure switch / MacPress</title>
		<link>https://szivattyuvezerles.hu/pressure-switch-macpress/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Tue, 09 Sep 2014 11:00:44 +0000</pubDate>
				<category><![CDATA[Pressure switch for water]]></category>
		<category><![CDATA[Pressure switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=3100</guid>

					<description><![CDATA[<p>MacPress is a regular pressure switch for hidrofor systems with expansion vessel. MacPress must be installed on the pipe, where it can sense the system&#8217;s pressure. The device operates between two pressure value: a starting, and a stopping pressure value. When the system&#8217;s pressure drops below the pre-set start pressure (by opening a tap), MacPress [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-macpress/">Pressure switch / MacPress</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water.png"><img fetchpriority="high" decoding="async" class="aligncenter  wp-image-3101" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water-640x370.png" alt="MacPress-pressure-switch-for-water" width="490" height="283" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water-640x370.png 640w, https://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water-600x347.png 600w, https://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water-277x160.png 277w, https://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water-624x361.png 624w, https://szivattyuvezerles.hu/wp-content/uploads/2014/09/MacPress-pressure-switch-for-water.png 784w" sizes="(max-width: 490px) 100vw, 490px" /></a></p>
<p>MacPress is a regular pressure switch for hidrofor systems with expansion vessel.</p>
<p>MacPress must be installed on the pipe, where it can sense the system&#8217;s pressure. The device operates between two pressure value: a starting, and a stopping pressure value.</p>
<p>When the system&#8217;s pressure drops below the pre-set start pressure (by opening a tap), MacPress sense it, and start the pump. When the water collecting process is over, and we close the tap, the pressure will increase. When the pressure reach the pre-set stopping value, stop the pump.</p>
<p>The housing colors: <span style="color: #3366ff;">Blue is one phase</span>, <span style="color: #f51414;">red is three phase</span></p>
<table width="346">
<tbody>
<tr>
<td width="154"><span style="color: #000000;"><strong>Mounting</strong></span></td>
<td width="192"><span style="color: #000000;"><strong>On pipe</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Protection rating</strong></span></td>
<td><span style="color: #000000;"><strong>IP 44</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Operating temperature</strong></span></td>
<td><span style="color: #000000;"><strong>0°C ÷ +50°C</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Connections</strong></span></td>
<td><span style="color: #000000;"><strong>1/4&#8243; F (can be ordered 1/2&#8243; F)</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Rated Current</strong></span></td>
<td><span style="color: #000000;"><strong>16 (10) and 25 (16) A</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Power supply</strong></span></td>
<td><span style="color: #000000;"><strong>117 / 230 / 400 V~ 50-60Hz</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Approval</strong></span></td>
<td><span style="color: #000000;"><strong>CE</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Dimensions</strong></span></td>
<td><span style="color: #000000;"><strong>112 x 105 x 55 mm</strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong>Weight</strong></span></td>
<td><span style="color: #000000;"><strong>0,37 kg</strong></span></td>
</tr>
</tbody>
</table>
<table width="338">
<tbody>
<tr>
<td style="text-align: center;" width="51"><span style="color: #000000;"><strong>Modell</strong></span></td>
<td style="text-align: center;" width="84"><span style="color: #000000;"><strong>Line Voltage</strong></span></td>
<td style="text-align: center;" width="103"><span style="color: #000000;"><strong>Factory settings</strong></span></td>
<td style="text-align: center;" width="100"><span style="color: #000000;"><strong>Pressure range</strong></span></td>
</tr>
<tr>
<td><strong><span style="color: #3366ff;">MPM3</span></strong></td>
<td><strong><span style="color: #3366ff;">One phase</span></strong></td>
<td><strong><span style="color: #3366ff;">2 &#8211; 3 bar</span></strong></td>
<td><strong><span style="color: #3366ff;">1,5 &#8211; 6 bar</span></strong></td>
</tr>
<tr>
<td><strong><span style="color: #3366ff;">MPM6</span></strong></td>
<td><strong><span style="color: #3366ff;">One phase</span></strong></td>
<td><strong><span style="color: #3366ff;">4 &#8211; 5,5 bar</span></strong></td>
<td><strong><span style="color: #3366ff;">4 &#8211; 10 bar</span></strong></td>
</tr>
<tr>
<td><strong><span style="color: #f51414;">MPT3</span></strong></td>
<td><strong><span style="color: #f51414;">Three phase</span></strong></td>
<td><strong><span style="color: #f51414;">2 &#8211; 3 bar</span></strong></td>
<td><strong><span style="color: #f51414;">1,5 &#8211; 6 bar</span></strong></td>
</tr>
<tr>
<td><strong><span style="color: #f51414;">MPT6</span></strong></td>
<td><strong><span style="color: #f51414;">Three phase</span></strong></td>
<td><strong><span style="color: #f51414;">4 &#8211; 5,5 bar</span></strong></td>
<td><strong><span style="color: #f51414;">4 &#8211; 10 bar</span></strong></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-macpress/">Pressure switch / MacPress</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pressure switch for water system applications / PM5; PT/5; PM/6; PT/6; PM/12; PT/12</title>
		<link>https://szivattyuvezerles.hu/pressure-switch-for-water-system-applications-pm5-pt5-pm6-pt6-pm12-pt12/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Thu, 05 Jun 2014 06:40:03 +0000</pubDate>
				<category><![CDATA[Pressure switch for water]]></category>
		<category><![CDATA[Pressure switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=1298</guid>

					<description><![CDATA[<p>Pressure switch for normal hidrofor system (with expansion vessel). Operates between two pressure value (starting and stopping). When the pressure in the system drops below the starting value, the pressure switch start the pump. As soon as the pressure increase in the system, and reach the stopping value, the pressure switch will shut down the [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-for-water-system-applications-pm5-pt5-pm6-pt6-pm12-pt12/">Pressure switch for water system applications / PM5; PT/5; PM/6; PT/6; PM/12; PT/12</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch.png"><img decoding="async" class="aligncenter  wp-image-3109" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch.png" alt="PM-pressure-switch" width="299" height="300" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch.png 403w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch-300x300.png 300w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch-100x100.png 100w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch-277x278.png 277w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM-pressure-switch-208x208.png 208w" sizes="(max-width: 299px) 100vw, 299px" /></a>Pressure switch for normal hidrofor system (with expansion vessel).</p>
<p style="text-align: justify;">Operates between two pressure value (starting and stopping). When the pressure in the system drops below the starting value, the pressure switch start the pump. As soon as the pressure increase in the system, and reach the stopping value, the pressure switch will shut down the pump.</p>
<table width="592">
<tbody>
<tr>
<td style="color: #000000;" width="142"></td>
<td style="color: #000000;" width="85"><strong>PM/5</strong></td>
<td style="color: #000000;" width="85"><strong>PT/6</strong></td>
<td style="color: #000000;" width="63"><strong>PM/12</strong></td>
<td style="color: #000000;" width="77"><strong>PT/5</strong></td>
<td style="color: #000000;" width="77"><strong>PT/6</strong></td>
<td style="color: #000000;" width="63"><strong>PT/12</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>Pressure range</strong></td>
<td style="color: #000000;"><strong>1 – 5 bar</strong></td>
<td style="color: #000000;"><strong>1.5 – 5.5 bar</strong></td>
<td style="color: #000000;"><strong>3 – 12 bar</strong></td>
<td style="color: #000000;"><strong>1 – 5 bar</strong></td>
<td style="color: #000000;"><strong>1.5 – 5.5 bar</strong></td>
<td style="color: #000000;"><strong>3 – 12 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>Factory settings</strong></td>
<td style="color: #000000;"><strong>1.4 – 2.8 bar</strong></td>
<td style="color: #000000;"><strong>1.8 – 3 bar</strong></td>
<td style="color: #000000;"><strong>5 – 7 bar</strong></td>
<td style="color: #000000;"><strong>1.4 – 2.8 bar</strong></td>
<td style="color: #000000;"><strong>1.8 – 3 bar</strong></td>
<td style="color: #000000;"><strong>5 – 7 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>Min. differential</strong></td>
<td style="color: #000000;"><strong>0.6 bar</strong></td>
<td style="color: #000000;"><strong>0.8 bar</strong></td>
<td style="color: #000000;"><strong>1.5 bar</strong></td>
<td style="color: #000000;"><strong>0.6 bar</strong></td>
<td style="color: #000000;"><strong>0.8 bar</strong></td>
<td style="color: #000000;"><strong>1.5 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>Max. differential</strong></td>
<td style="color: #000000;"><strong>2.3 bar</strong></td>
<td style="color: #000000;"><strong>2.2 bar</strong></td>
<td style="color: #000000;"><strong>5 bar</strong></td>
<td style="color: #000000;"><strong>2.3 bar</strong></td>
<td style="color: #000000;"><strong>2.2 bar</strong></td>
<td style="color: #000000;"><strong>5 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>Rated current</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>Rated voltage</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-for-water-system-applications-pm5-pt5-pm6-pt6-pm12-pt12/">Pressure switch for water system applications / PM5; PT/5; PM/6; PT/6; PM/12; PT/12</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pressure switch to water pumps with integrated pressure gauge and 3 way fittings / PM/5-3W; PM/5-2W</title>
		<link>https://szivattyuvezerles.hu/pressure-switch-to-water-pumps-with-integrated-pressure-gauge-and-3-way-fittings-pm5-3w-pm5-2w/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Thu, 05 Jun 2014 06:33:05 +0000</pubDate>
				<category><![CDATA[Pressure switch for water]]></category>
		<category><![CDATA[Pressure switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=1296</guid>

					<description><![CDATA[<p>PM/5-3 W PM/5-2 W This pressure switch is a PM/5 but widen with a housing. The housing contain 3 or 2 threads (see the data sheet) for easy install on the hidrofor system, and a pressure gauge. The operation principle is the same as the PM/5 pressure switch: Operates between two pressure value (starting and stopping). When [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-to-water-pumps-with-integrated-pressure-gauge-and-3-way-fittings-pm5-3w-pm5-2w/">Pressure switch to water pumps with integrated pressure gauge and 3 way fittings / PM/5-3W; PM/5-2W</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3.png"><img decoding="async" class="wp-image-3113 aligncenter" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3.png" alt="PM5-3" width="334" height="334" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3.png 440w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3-300x300.png 300w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3-100x100.png 100w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3-424x424.png 424w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3-277x277.png 277w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-3-208x208.png 208w" sizes="(max-width: 334px) 100vw, 334px" /></a></p>
<h1 style="text-align: center;"><em><span style="color: #999999;">PM/5-3 W<img loading="lazy" decoding="async" class="aligncenter wp-image-3115" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2.png" alt="PM5-2" width="334" height="334" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2.png 440w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2-300x300.png 300w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2-100x100.png 100w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2-424x424.png 424w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2-277x277.png 277w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2-208x208.png 208w" sizes="auto, (max-width: 334px) 100vw, 334px" /></span></em></h1>
<h1 style="text-align: center;"><span style="color: #999999;"><em>PM/5-2 W</em></span></h1>
<p><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PM5-2.png"><br />
</a>This pressure switch is a <a title="Pressure switch for water system applications / PM5; PT/5; PM/6; PT/6; PM/12; PT/12" href="http://szivattyuvezerles.hu/pressure-switch-for-water-system-applications-pm5-pt5-pm6-pt6-pm12-pt12/">PM/5</a> but widen with a housing. The housing contain 3 or 2 threads (see the data sheet) for easy install on the hidrofor system, and a pressure gauge.</p>
<p>The operation principle is the same as the <a title="Pressure switch for water system applications / PM5; PT/5; PM/6; PT/6; PM/12; PT/12" href="http://szivattyuvezerles.hu/pressure-switch-for-water-system-applications-pm5-pt5-pm6-pt6-pm12-pt12/">PM/5</a> pressure switch:</p>
<p>Operates between two pressure value (starting and stopping). When the pressure in the system drops below the starting value, the pressure switch start the pump. As soon as the pressure increase in the system, and reach the stopping value, the pressure switch will shut down the pump.</p>
<table width="580">
<tbody>
<tr>
<td style="color: #000000;" width="240"></td>
<td style="color: #000000;" width="170"><strong>PM/5-3W</strong></td>
<td style="color: #000000;" width="170"><strong>PM/5-2W</strong></td>
</tr>
<tr>
<td style="color: #000000;"><em><strong>Pressure range</strong></em></td>
<td style="color: #000000;"><strong>1 – 5 bar</strong></td>
<td style="color: #000000;"><strong>1.5 – 5.5 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Factory settings</i></b></td>
<td style="color: #000000;"><strong>1.4 – 2.8 bar</strong></td>
<td style="color: #000000;"><strong>1.8 – 3 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Min. differental</i></b></td>
<td style="color: #000000;"><strong>0.6 bar</strong></td>
<td style="color: #000000;"><strong>0.8 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Max. differentak</i></b></td>
<td style="color: #000000;"><strong>2.3 bar</strong></td>
<td style="color: #000000;"><strong>2.2 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Rated current</i></b></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Rated voltage</i></b></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong>250 V</strong></td>
</tr>
<tr>
<td style="color: #000000;" rowspan="3"><em><strong>Connections</strong></em></td>
<td style="color: #000000;"><strong>1″ Male</strong></td>
<td style="color: #000000;"><strong>1/4″ Male</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>1″ Female</strong></td>
<td style="color: #000000;"><strong>1″ Female</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong>1″ Female</strong></td>
<td style="color: #000000;"><strong>&#8211;</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Pressure gauge</i></b></td>
<td style="color: #000000;"><strong>Ø 40 mm 0-6 bar / 0-86 PSI</strong></td>
<td style="color: #000000;"><strong>Ø 40 mm 0-6 bar / 0-86 PSI</strong></td>
</tr>
</tbody>
</table>
<p>In case of direct connections (when the MP/5-3 W turn on/off the motor), the motor’s power cannot be higher than 1.1 kW. With an adequacy magnetic switch it can be increased.</p>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-to-water-pumps-with-integrated-pressure-gauge-and-3-way-fittings-pm5-3w-pm5-2w/">Pressure switch to water pumps with integrated pressure gauge and 3 way fittings / PM/5-3W; PM/5-2W</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pressure switch with SPDT contact</title>
		<link>https://szivattyuvezerles.hu/pressure-switch-with-spdt-contact-ps3-ps5-ps12/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Thu, 05 Jun 2014 06:23:42 +0000</pubDate>
				<category><![CDATA[Pressure switch for water]]></category>
		<category><![CDATA[Pressure switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=1292</guid>

					<description><![CDATA[<p>PS pressure switches are for different technological water system control. They are used most in firefight water systems. With the SPDT relay contact, can operate two pump at once: If the electric pump stop by any malfunction, the pressure in the firefight water system will cease. The pressure switch sense the drop, and the SPDT [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-with-spdt-contact-ps3-ps5-ps12/">Pressure switch with SPDT contact</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS3-SPDT-contact-pressure-switch.jpg"><img loading="lazy" decoding="async" class=" wp-image-2804 aligncenter" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS3-SPDT-contact-pressure-switch.jpg" alt="PS3-SPDT-contact-pressure-switch" width="302" height="328" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS3-SPDT-contact-pressure-switch.jpg 374w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS3-SPDT-contact-pressure-switch-277x300.jpg 277w" sizes="auto, (max-width: 302px) 100vw, 302px" /></a></p>
<p>PS pressure switches are for different technological water system control. They are used most in firefight water systems. With the SPDT relay contact, can operate two pump at once:</p>
<p>If the electric pump stop by any malfunction, the pressure in the firefight water system will cease. The pressure switch sense the drop, and the SPDT microswitch will switch on a pump drived by petrol engine.</p>
<div id="attachment_3121" style="width: 556px" class="wp-caption aligncenter"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3121" class="wp-image-3121 size-full" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS-PRESSURE-SWITCH.png" alt="PS-PRESSURE-SWITCH" width="546" height="474" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS-PRESSURE-SWITCH.png 546w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS-PRESSURE-SWITCH-277x240.png 277w" sizes="auto, (max-width: 546px) 100vw, 546px" /><p id="caption-attachment-3121" class="wp-caption-text">The fire sprinkler system supplied by the electric pump.</p></div>
<div id="attachment_3122" style="width: 556px" class="wp-caption aligncenter"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3122" class="wp-image-3122 size-full" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS-PRESSURE-SWITCH-2.png" alt="PS-PRESSURE-SWITCH 2" width="546" height="474" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS-PRESSURE-SWITCH-2.png 546w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/PS-PRESSURE-SWITCH-2-277x240.png 277w" sizes="auto, (max-width: 546px) 100vw, 546px" /><p id="caption-attachment-3122" class="wp-caption-text">The electric pump failed, the pressure dropped. PS pressure switch sense the pressure drop, and switched to the petrol engine pump.</p></div>
<table width="583">
<tbody>
<tr>
<td width="192"><span style="color: #000000;"><strong>Data sheet</strong></span></td>
<td width="71"><span style="color: #000000;"><strong>PS/3</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>PS/3D</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>PS/5</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>PS/5D</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>PS/12</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>PS/12D</strong></span></td>
</tr>
<tr>
<td width="192"><em><span style="color: #000000;"><strong>Max. factory pressure</strong></span></em></td>
<td width="71"><span style="color: #000000;"><strong>5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>12 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>12 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>12 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>12 bar</strong></span></td>
</tr>
<tr>
<td width="192"><em><span style="color: #000000;"><strong>Pre-set pressure</strong></span></em></td>
<td width="71"><span style="color: #000000;"><strong>0.9 &#8211; 2 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.9 &#8211; 5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>1.7 &#8211; 5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>1.7 &#8211; 7.5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>2.5 &#8211; 10 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>2.5 &#8211; 12 bar</strong></span></td>
</tr>
<tr>
<td width="192"><em><span style="color: #000000;"><strong>Min. pressure differential </strong></span></em></td>
<td width="71"><span style="color: #000000;"><strong>0.2 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.4 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.8 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.8 bar</strong></span></td>
</tr>
<tr>
<td width="192"><em><span style="color: #000000;"><strong>Max. pressure differential </strong></span></em></td>
<td width="71"><span style="color: #000000;"><strong>0.2 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>2.5 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>0.7 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>3.3 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>1.4 bar</strong></span></td>
<td width="64"><span style="color: #000000;"><strong>3.8 bar</strong></span></td>
</tr>
<tr>
<td width="192"><em><span style="color: #000000;"><strong>Max. voltage</strong></span></em></td>
<td colspan="6" width="391">
<p style="text-align: center;"><span style="color: #000000;"><strong>5 A &#8211; 250 V</strong></span></p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://szivattyuvezerles.hu/pressure-switch-with-spdt-contact-ps3-ps5-ps12/">Pressure switch with SPDT contact</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Low pressure switch / LP/3D; LP/3-18</title>
		<link>https://szivattyuvezerles.hu/low-pressure-switch-lp3d-lp3-18/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Thu, 05 Jun 2014 06:18:18 +0000</pubDate>
				<category><![CDATA[Pressure switch for water]]></category>
		<category><![CDATA[Termékeink]]></category>
		<category><![CDATA[Pressure switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=1290</guid>

					<description><![CDATA[<p>Pressure switch for the protection of water systems (autoclave and fi re-fi ghting systems) and pneumatic systems (control circuits under pressure) The device interrupts the electric connection between the line and the load when the pressure decreases below the established value (stop pressure) In the autoclave systems it is matched in series with a PM/5 [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/low-pressure-switch-lp3d-lp3-18/">Low pressure switch / LP/3D; LP/3-18</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: center;"><strong><span style="color: red;"><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch.png"><img loading="lazy" decoding="async" class="alignnone  wp-image-2809" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch.png" alt="LP3-low-pressure-switch" width="280" height="280" srcset="https://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch.png 396w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch-300x300.png 300w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch-100x100.png 100w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch-277x277.png 277w, https://szivattyuvezerles.hu/wp-content/uploads/2014/06/LP3-low-pressure-switch-208x208.png 208w" sizes="auto, (max-width: 280px) 100vw, 280px" /></a></span></strong></h3>
<ul>
<li>Pressure switch for the protection of water systems (autoclave and fi re-fi ghting systems) and pneumatic systems (control circuits under pressure)</li>
<li>The device interrupts the electric connection between the line and the load when the pressure decreases below the established value (stop pressure)</li>
<li>In the autoclave systems it is matched in series with a PM/5 pressure switch in order to protect the electric pump from dry running</li>
<li>The reset is automatic when the pressure becomes again higher than the start value or when pressing the reset button</li>
<li>Double electric contact: normally open, made of brass alloy with Ag-Ni surfacing</li>
<li>Terminals with M4 screws and 8&#215;8 mm pressure dice</li>
<li>NBR rubber membrane with food grade textile insert</li>
<li>¼&#8221; F hydraulic connection made of galvanised steel</li>
<li>Standard protection degree IP 44</li>
<li>Max ambient temperature: 55°C</li>
<li>Tear resistant cable clamps</li>
</ul>
<h3 style="text-align: center;"><strong><span style="color: red;">Warning!</span></strong></h3>
<p><strong>The pressure of the watercolum within the pipes cannot be greater than the stop pressure.</strong></p>
<table width="312">
<tbody>
<tr>
<td style="color: #000000;" width="142"></td>
<td style="color: #000000;" width="85"><strong>LP/3</strong></td>
<td style="color: #000000;" width="85"><strong>LP/3 – 18</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Cut-out (pump stop) pressure</i></b></td>
<td style="color: #000000;"><strong>0.05 – 0.4 bar</strong></td>
<td style="color: #000000;"><strong>0.5 – 2 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Cut-in (pump start) pressure</i></b></td>
<td style="color: #000000;"><strong>0.4 – 0.75 bar</strong></td>
<td style="color: #000000;"><strong>0.95 – 2.6 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Factory settings</i></b></td>
<td style="color: #000000;"><strong>0.1 – 0.5 bar</strong></td>
<td style="color: #000000;"><strong>0.5 – 0.95 bar</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong><em>Rated current </em></strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
</tr>
<tr>
<td style="color: #000000;"><b><i>Rated voltage</i></b></td>
<td style="color: #000000;"><strong>250 V</strong></td>
<td style="color: #000000;"><strong><strong>250 V</strong></strong></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://szivattyuvezerles.hu/low-pressure-switch-lp3d-lp3-18/">Low pressure switch / LP/3D; LP/3-18</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Vacuum switch &#124; VC100SW</title>
		<link>https://szivattyuvezerles.hu/vacuum-switch-vc100sw/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Thu, 05 Jun 2014 06:14:07 +0000</pubDate>
				<category><![CDATA[Pressure switch for water]]></category>
		<category><![CDATA[Pressure switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=1288</guid>

					<description><![CDATA[<p>Vacuum switch, useful for protecting the pump against dry running during draining of basins, tanks or cisterns The switch, which is fi tted on the suction pipe, controls the vacuum generated by the pump The system is activated manually using the start lever which, when lowered, starts the pump running; this action leads to the [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/vacuum-switch-vc100sw/">Vacuum switch | VC100SW</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="size-full wp-image-1230 aligncenter" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/VC100-vacuum-switch.jpg" alt="VC100 vacuum switch" width="210" height="194" /></p>
<ul>
<li>Vacuum switch, useful for protecting the pump against dry running during draining of basins, tanks or cisterns</li>
<li>The switch, which is fi tted on the suction pipe, controls the vacuum generated by the pump</li>
<li>The system is activated manually using the start lever which, when lowered, starts the pump running; this action leads to the creation of the vacuum which automatically determines the closure of the contacts. When the liquid supply is about to run out, the vacuum in the suction line disappears and so the switch deactivates the pump</li>
<li>Variable distance between the switch and the end of the suction pipe (from 0 to 4 m / 0 to 157 ½ inches)</li>
<li>Normally open brass alloy contacts with Ag-Ni insert</li>
<li>Oil-resistant NBR rubber membrane</li>
<li>Max ambient temperature 55°C</li>
</ul>
<table width="410">
<tbody>
<tr>
<td style="color: #000000;" width="240"></td>
<td style="color: #000000;" width="170"><strong>VC100</strong></td>
</tr>
<tr>
<td style="color: #000000;"><em><strong>Connections</strong></em></td>
<td style="color: #000000;"><strong>1/4″ Female</strong></td>
</tr>
<tr>
<td style="color: #000000;"><em><strong>Rated voltage</strong></em></td>
<td style="color: #000000;"><strong>250 V</strong></td>
</tr>
<tr>
<td style="color: #000000;"><em><strong>Rated current</strong></em></td>
<td style="color: #000000;"><strong>16 (10) A</strong></td>
</tr>
<tr>
<td style="color: #000000;"><strong><em>Setting values</em></strong></td>
<td style="color: #000000;"><strong><strong>1.5 – 2 – 2.5 – 4 – 4.5 inHg</strong></strong></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://szivattyuvezerles.hu/vacuum-switch-vc100sw/">Vacuum switch | VC100SW</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		