<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Voltage switch Archives - Szivattyúvezérlés</title>
	<atom:link href="https://szivattyuvezerles.hu/tag/voltage-switch/feed/" rel="self" type="application/rss+xml" />
	<link>https://szivattyuvezerles.hu/tag/voltage-switch/</link>
	<description>szintszabályozás</description>
	<lastBuildDate>Wed, 13 May 2015 12:26:47 +0000</lastBuildDate>
	<language>hu</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>
	<item>
		<title>Electric pump voltage switch / Mito</title>
		<link>https://szivattyuvezerles.hu/electric-pump-voltage-switch-mito/</link>
		
		<dc:creator><![CDATA[Komár Péter]]></dc:creator>
		<pubDate>Wed, 04 Jun 2014 13:43:08 +0000</pubDate>
				<category><![CDATA[Flow sensor, VFD (Variable Frequency Drive)]]></category>
		<category><![CDATA[Voltage switch]]></category>
		<guid isPermaLink="false">http://szivattyuvezerles.hu/?p=1264</guid>

					<description><![CDATA[<p>Mito is an AC/AC chopper driver for single phase electric pumps. The device was designed to domestic usage, where the where supply demands are medium-short term and generally timed over the space of one day. Mito regulate the tension of the pump, and holding the pressure to a constant value in the system. Furthermore protects the [&#8230;]</p>
<p>The post <a href="https://szivattyuvezerles.hu/electric-pump-voltage-switch-mito/">Electric pump voltage switch / Mito</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/Voltage-switch-pump-control-Mito.jpg"><img decoding="async" class="size-full wp-image-1238 aligncenter" src="http://szivattyuvezerles.hu/wp-content/uploads/2014/06/Voltage-switch-pump-control-Mito.jpg" alt="Voltage switch pump control Mito" width="174" height="212" /></a></p>
<p>Mito is an AC/AC chopper driver for single phase electric pumps. The device was designed to domestic usage, where the where supply demands are medium-short term and generally timed over the space of one day.</p>
<p>Mito regulate the tension of the pump, and holding the pressure to a constant value in the system. Furthermore protects the pump from dry running, and with the relays, we can install an alarm system, or connect float, or pressure switches to the device.</p>
<p>The pump is initially started at maximum speed and is then progressively adjusted depending on the flow required. In this way, output pressure is supplied at a constant rate for greater comfort.</p>
<p>Pressure is regulated for a maximum time interval (settable in the parameter &#8222;Cool mode&#8221; from 5 to 30 minutes according to the type of pump), during which supply demand should expire. When this period elapses, if the demand for water supply persists, the pump motor is set to maximum speed to avoid overheating, caused by reduced ventilation. On closure of all supply points, pump shutdown and consequent cooling of the motor enables reset of the regulation time for the next pump start-up cycle, in relation to the pause time and operation time (one minute shutdown corresponds to one minute of regulation in the next cycle).</p>
<table width="491">
<tbody>
<tr>
<td width="196"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Power mains supply:</span></span></strong></span></td>
<td width="295"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">230 V~ ±10% 50/60Hz single phase</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Motor power output:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">230 V~ single phase</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Max. motor power:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">750 W</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Max. line absorption:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">6 A @ 230 V~</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Max allowed pressure</span></span></strong></span></td>
<td width="295"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">8 bar</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Max fluid temperature:</span></span></strong></span></td>
<td width="295"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">30 °C</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Pressure drop:</span></span></strong></span></td>
<td width="295"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">0,7 bar at 150 l/min</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Set point adjustement range:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">1,5 &#8211; 5 bar</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Start pressure adjustment range:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">1 &#8211; 6,7 bar</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Hydraulic connection:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">1&#8243; ¼ male &#8211; male</span></span></strong></span></td>
</tr>
<tr>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Voltage modulation range:</span></span></strong></span></td>
<td><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">230÷170 V</span></span></strong></span></td>
</tr>
<tr>
<td width="196"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">Protection degree:</span></span></strong></span></td>
<td width="295"><span style="color: #000000;"><strong><span style="font-size: 14px; line-height: 14px;"><span style="font-family: 'Open Sans', Helvetica, Arial, sans-serif;">IP 65</span></span></strong></span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://szivattyuvezerles.hu/electric-pump-voltage-switch-mito/">Electric pump voltage switch / Mito</a> appeared first on <a href="https://szivattyuvezerles.hu">Szivattyúvezérlés</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>